CAP10AD62

Use Socket: 70170-D

May not be exact product—for reference only.

  • CURRENT SENSING RELAY
  • 5ma - 10A DC
  • START-UP SENSING DELAY: 0.1 - 10 SEC.
  • 120V AC
  • 10A SPDT
Description Of Function Non-Latching Mode:The unit will operate in the non-latching mode if no circuit is completed across pins 9 & 11 on power-up. After input voltage is applied (LED is Green) and the start-up sensing delay (ts) of 0.1 – 10 seconds is completed, the relay will energize when the monitored current is above the adjustable pick-up setting (“Threshold”) and the LED will be Red. It will de-energize when the monitored current goes below the adjustable drop-out setting (“Hysteresis”) by 5-50% of the selected pick-up setting or when input voltage is removed. The LED will be Green.

Latching Mode:
The unit will operate in the latching mode if a N.C. contact (Memory S2) is onnected across pins 9 & 11 on power-up (see Wiring Diagram). After input voltage is applied (LED is Green) and the start-up sensing delay (ts) of 0.1 – 10 seconds is completed, the relay will energize when the monitored current is above the adjustable pick-up setting (“Threshold”) and the LED will be Red. It will de-energize when the monitored current goes below the adjustable drop-out setting (“Hysteresis”) by 5-50% of the selected pick-up setting and the N.C. contact (Memory S2) is opened, or when input voltage is removed. The LED will be Green. It is recommended to set the Hysteresis at 5% when in the latching mode.
Function Chart
Application Information
  • Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz.
  • Load (Burden): Less than 5VA for all voltages
  • Indicator LED: Green when Input Voltage is applied; Red when Relay is energized
  • Monitored Current Ranges:
    Three built-in current ranges to monitor both AC & DC current: 5 -100ma DC (3.5 - 70.7ma AC); 0.05 - 1A DC (0.035 - 0.707A AC); and 0.5 - 10A DC (0.35 - 7.07A AC)
  • Response Times:
    Sensing delay on power-up ts: 0.1 - 10 seconds
    Pick-up & Drop-out: Fixed 100ms
  • Output Contacts: 10A @ 240V AC / 7A @ 28V DC SPDT, 1/4 HP @ 120V AC (N.O.)
  • Life: Mechanical: 10,000,000 operations; Full Load: 100,000 operations
  • Temperature: -28o to 65o C (-18o to 149o F)
  • Approvals:

    c-ur-us.jpg  UL-socket.jpg
Dimensions - Inches (Millimeters)
Macromatic Distributor Stock Status
  • Allied Distributor Part #: 71307820 Info/Buy

  • Grainger Distributor Part #: 485R27 Info/Buy

Contact Macromatic

Fill out this form to have Macromatic contact you about this product.

©2024 Macromatic Industrial Controls, Inc.

2201 Corporate Drive
Waukesha, WI 53189

800-238-7474 • 262-781-3366

Rep Login | Newsletter Sign Up | Articles | Employment | Privacy Policy | Sitemap
Knowledgebase General | Alternating Relays | Current Sensing Relays | Intrinsically Safe Barrier Relays | Liquid Level Control Relays | Seal Leak Relays | Three-Phase Monitor Relays | Time Delay Relays | Voltage Monitor Relays